Looking for larger lengths? Most bulk fiber is available in reels up to 13,000 Feet. Give us a call at 800-626-6622 to get a quote.
24 Fiber 62.5/125µm OM1 Ultra-Fox™ Indoor/Outdoor Plenum Orange Jacket Indoor/outdoor tight-buffered design allows cables to be installed in intra-building backbone and inter-building campus locations without costly transitions between cable types. Ideal configuration for a single termination point requiring multiple fibers. 900μm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices, because connectors terminate directly to the fiber. No need to splice outdoor cable to indoor cable at building entranceHigh crush resistance may eliminate the need for innerduct.
- Features
- UL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces
- Fluorpolymer jacket
- 2 to 72 fibers
- Cable materials are Indoor/Outdoor UL-Listed OFNP and also UV, chemical, water and fungus resistant
- Jacket is highly chemical resistant for installation in harsh industrial environments
- High performance tight-buffered coating on each fiber for environmental and mechanical protection
- 900 µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber.
- Helically stranded core for flexibility, survival in difficult installations, and mechanical protection for the fibers
- High specific strength-to-weight ratio and compact cable design for limited conduit space and tight bends in long cable pulls
- High crush resistance may eliminate the need for innerduct
- Can be installed outside and in plenum or riser pathways inside, eliminating the need to transition cable types between environments
- Interlocking armor can be applied to cables as an alternative to conduit installation
- Standards
- UL 1651
- ANSI/NFPA 262
- GR-409-CORE
- ICEA-S-104-696
- ICEA-S-83-596
- TIA-568
- TIA-598
- UL-listed type OFNP in accordance with NEC sections 770-179 (A) and 770-154 (A) for use in ducts, plenums, and air-handling spaces. Meets or exceeds requirements for intra-building fiber optic cables as outlined in GR-409-CORE.
- Fiber Specs
- Fiber Count: 24
- Core/Cladding Diameter (µm): 62.5/125
- Numeric Aperture: 0.275
- Wavelength (nm): 850/1310
- Gigabit Ethernet Distance (m): 300/600
- 10-Gigabit Ethernet Distance (m): 33/300ˆ
- Maximum Cabled Attenuation (dB/km): 3.5/1.5
- Minimum Laser EMB Bandwidth* (MHz-km): 220/500
- Minimum OFL LED Bandwidth** (MHz-km): 200/500